Gemakkelijk te installeren, in bedrijf te stellen en te bedienen
Vermindert de bedrijfskosten
Verhoogt de energie-efficiëntie in verwarmings- en koelsystemen
Tryckhållningsenhet TTM GeniX®
Installation benefits:
- Easy to install, put into operation and operate
- Can be installed in both smaller and larger heating systems
- Intuitivt gränssnitt med pekskärm för injustering och övervakning
- Easy to control with an intuitive touch screen for operation and monitoring
- Low weight – easy to transport
- The expansion vessel is available in various sizes.
Operationele voordelen:
- Keeps the operation pressure constant in the entire heatning system
- Sensors with alarm connected to deviations, pump, fluid level
- Noice level under 70db
- Minimal maintenance is required
- The automation for control, regulation and monitoring is connected via Modbus-RTU.
- Easy to install, put into operation and operate
- Can be installed in both smaller and larger heating systems
- Intuitivt gränssnitt med pekskärm för injustering och övervakning
- Easy to control with an intuitive touch screen for operation and monitoring
- Low weight – easy to transport
- The expansion vessel is available in various sizes.
- Keeps the operation pressure constant in the entire heatning system
- Sensors with alarm connected to deviations, pump, fluid level
- Noice level under 70db
- Minimal maintenance is required
- The automation for control, regulation and monitoring is connected via Modbus-RTU.
Intuitive touch screen. The intuitive 3.5” color touch screen makes the TTM GeniX® GE18 easy to use.
The TTM GeniX® should be installed and used by authorized operating personnel. The pressurization unit is placed in a heated room and connected to the heating system return line (connector G25). Start-up is initiated by connecting the plug to an earthed wall socket (230V, 10A).
The system pressure sensor controls the pressure maintenance pump during filling and a solenoid valve regulates emptying. Pressure maintenance pump location close to the suction side helps to minimise the risk of negative pressure build-up. In this way, a constant operating pressure is maintained in the heating system at both heating and cooling
The pressure sensor in the water-filled expansion vessel displays the current level on the display. If the level in the vessel becomes too low, this is shown on the display with an alarm indication and via alarm relay for external indication.
TTM GeniX® is designed for permanent installation in both new and existing heating systems.
1. Expansion line (Thread 25 mm)
2. Filling pipe (Thread 15 mm)
3. Filling pipe (Thread 15 mm)
4. Level sensor
5. Power cable with plug
The expansion vessel can be connected in series and combined to the desired volume.
Model | GE18 110L / 4 | GE18 200L / 4 | GE18 300L / 4 | GE18 500L / 4 | GE18 110L / 6 | GE18 200L / 6 | GE18 300L / 6 | GE18 500L / 6 |
---|---|---|---|---|---|---|---|---|
Art.no | 514046 | 514053 | 514060 | 514077 | 514091 | 514107 | 514114 | 514121 |
Operating pressure (bar) | 3.0 | 3.0 | 3.0 | 3.0 | 6.0 | 6.0 | 6.0 | 6.0 |
Vessel volume (Litre) | 110 | 200 | 300 | 500 | 110 | 200 | 300 | 500 |
Diameter D (Ømm) | 450 | 520 | 650 | 750 | 450 | 520 | 650 | 750 |
Height H (mm) | 1080 | 1190 | 1135 | 1385 | 1080 | 1190 | 1135 | 1385 |
Media temp. (°C) | +5 – +70 | +5 – +70 | +5 – +70 | +5 – +70 | +5 – +70 | +5 – +70 | +5 – +70 | +5 – +70 |
Ambient temp. (°C) | +10 – +40 | +10 – +40 | +10 – +40 | +10 – +40 | +10 – +40 | +10 – +40 | +10 – +40 | +10 – +40 |
Pressure class (PN) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Allowed liquids | Kranvatten | Kranvatten | Kranvatten | Kranvatten | Kranvatten | Kranvatten | Kranvatten | Kranvatten |
Connection dim. | G25 | G25 | G25 | G25 | G25 | G25 | G25 | G25 |
Electrical data | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz |
Ext. fuse (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated power (kW) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Voltage (plug) | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz | 1 ~ 230 V, 50 Hz |
Rated current (A) | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A | 3.1 – 2.8 A |
Protection class (IP) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Noise level (dB) | under 70 | under 70 | under 70 | under 70 | under 70 | under 70 | under 70 | under 70 |
Modbus RTU | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Weight (kg) | 34 | 34 | 38 | 44 | 35 | 35 | 39 | 45 |
TTM Aansluitslang
TTM-aansluitslang is een glycolbestendige verbindingsslang die een staalgewonden EPDM-slang is die geschikt is voor drukken tot 10 bar.
TTM Aansluitslang 1000 DN15
Lengte: 1 m
Art.nr.: 505433
TTM Aansluitslang 1500 DN15
Lengte: 1,5 m
Art.nr.: 505440
Wanneer Kanico een nieuwe wijk in Borås ontwikkelt, is TTM verantwoordelijk voor de shuntgroepen in de HVAC-systemen. Het gebied heet Simonsland en omvat 60.000 vierkante meter aan gebouwen.
Het Operahuis van Kopenhagen heeft een oppervlakte van 41.000 vierkante meter, 14 verdiepingen, met 6 podia, een hoofdpodium voor ongeveer 1.500 toeschouwers en 5 podia voor repetities en voorbereidingen.
NCC bouwt zijn nieuwe hoofdkantoor op Järva Krog in Solna. Het nieuwe hoofdkantoor zal strategisch gelegen zijn op een gemakkelijk bereikbare locatie dicht bij de E4-snelweg.