TTM SHUNTOMATIC® MINI bestelgids

Shunt unit Heating Connection internal (mm) Flow range Min. avail. pressure sec (kPa) Max. loading pressure drop sec (kPa) Max. effect (kW) at ΔT 30°C Pump option Effect (W) Rate current (A) Voltage (V) Download CAD file Art.no.
l/s l/h
min max min max min max min max min max
V MINI 1 Ø25 0.010 0.017 35 60 17.0 20.0 50 47 1.2 2.1 Standard 40 0.4 1×230 513360
Communication* 100 1.0 1×230 513377
V MINI 2 Ø25 0.017 0.031 60 110 17.0 20.0 53 50 2.1 3.8 Standard 40 0.4 1×230 513384
Communication* 100 1.0 1×230 513391
V MINI 3 Ø25 0.028 0.050 100 180 17.0 21.0 55 52 3.5 6.3 Standard 40 0.4 1×230 513407
Communication* 100 1.0 1×230 513414
V MINI 4 Ø25 0.050 0.106 180 380 18.0 22.5 45 51 6.6 1.0 Standard 40 0.4 1×230 513421
Communication* 100 1.0 1×230 513438
V MINI 5 Ø25 0.106 0.236 380 850 20.0 25.5 52 49 13 30 Standard 40 0.4 1×230 513445
Communication* 100 1.0 1×230 513452
V MINI 6 Ø25 0.192 0.369 690 1330 20.0 25.5 52 49 24 46 Standard 40 0.4 1×230 513469
Communication* 100 1.0 1×230 513476
Shuntomatic® is dimensioned for fresh water. *) Prepared for start. stop and alarm.1.0

TTM SHUNTOMATIC® bestelgids

Shunt unit Heating Connection internal (mm) Flow range Min. avail. pressure (kPa) Max. loading pressure drop sec (kPa) Max. effect (kW) at ΔT 30°C Pump option Effect (W) Rate current (A) Voltage (V) Download CAD file Art.no.
l/s l/h
min max min max min max min max min max
Shuntomatic® V DN15LF 0.008 0.056 30 200 15.0 16.0 52 45 1.0 7.0 Standard 40 0.4 1×230 516699
Communication* 100 1 1×230 516705
Shuntomatic® V DN15HF 0.028 0.160 100 575 15.0 19.5 52 43 3.5 20 Standard 40 0.4 1×230 517023
Communication* 100 1 1×230 516712
Shuntomatic® V DN25 0.078 0.347 280 1250 15.5 25.5 52 36 10 44 Standard 40 0.4 1×230 516729
Communication* 100 1 1×230 516736
Shuntomatic® V DN32 0.222 0.986 800 3550 18.5 29.5 68 55 28 124 Standard 40 0.4 1×230 516941
Communication* 100 1 1×230 516958
Shuntomatic® V DN50 0.625 2.639 2250 9500 10.5 29.5 110 42 78 331 Standard 40 1.3 1×230 516965
Communication* 100 1.3 1×230 516972
Shunt unit Cooling Connection internal (mm) Flow range Min. avail. pressure (kPa) Max. loading pressure drop sec (kPa) Max. effect (kW) at ΔT 5°C Pump option Effect (W) Rate current (A) Voltage (V) Download CAD file Art.no.
l/s l/h
min max min max min max min max min max
Shuntomatic® K DN15LF 0.008 0.056 30 200 15.0 16.0 52 45 0.2 1.2 Standard 40 0.4 1×230 516743
Communication* 100 1 1×230 516750
Shuntomatic® K DN15HF 0.028 0.160 100 575 15.0 19.5 52 43 0.6 3.3 Standard 40 0.4 1×230 516767
Communication* 100 1 1×230 516774
Shuntomatic® K DN25 0.078 0.347 280 1250 15.5 25.5 52 35 1.6 7.3 Standard 40 0.4 1×230 516781
Communication* 100 1 1×230 516798
Shuntomatic® K DN32 0.222 0.986 800 3550 18.5 29.5 68 54 4.6 21 Standard 40 0.4 1×230 516989
Communication* 100 1 1×230 516996
Shuntomatic® K DN50 0.625 2.639 2250 9500 10.5 29.5 110 41 13 55 Standard 40 1.3 1×230 517009
Communication* 100 1.3 1×230 517016
TTM Shuntomatic® is dimensioned for fresh water. *) Prepared for start, stop and alarm. DN32 and DN50 also have operation indication.

 

Montage optieArtikelnummer